Repeat Transcatheter Aortic Valve Replacement and Follow-Up of Embolized Transcatheter Heart Valve After 13 Years

oleh: Abdul Rahman Ihdayhid, MBBS, PhD, Janarthanan Sathananthan, MBChB, MPH, Richard Brown, MD, Philipp Blanke, MD, John G. Webb, MD

Format: Article
Diterbitkan: Elsevier 2021-04-01

Deskripsi

A 79-year-old woman was treated with a 23-mm balloon-expandable transcatheter heart valve (THV) that was initially complicated by an embolized THV requiring deployment in the descending aorta. She presented 13-years later with a degenerated bioprosthesis requiring redo THV. Pre-procedural computed tomography was important in highlighting underexpansion of the initial THV and open leaflets in the embolized valve. (Level of Difficulty: Advanced.)