X-ray Microtomography as a Non-Invasive Method for Evaluating the Stability of Commercial Effervescent Tablets

oleh: Michał Meisner, Piotr Duda, Beata Szulc-Musioł, Beata Sarecka-Hujar

Format: Article
Diterbitkan: MDPI AG 2023-05-01

Deskripsi

In the present study, a non-invasive X-ray microtomography technique was applied to assess the internal structure of commercial effervescent tablets with vitamin C. Expired tablets stored under ambient conditions were analyzed and the results obtained were compared with unexpired tablets. Significantly higher density values were found for the unexpired tablets (1.250 g/cm<sup>3</sup>) compared to the expired tablets (1.242 g/cm<sup>3</sup>). The results indicate a better homogeneity of the unexpired tablets, which may affect their mechanical strength.