Coaxial Placement of Fogarty Catheter: A Simple Remedy for Incomplete Lung Isolation with DLT

oleh: Amit Kumar Mittal, Anita Kulkarni, Ajay Kumar Bhargava, Soumi Pathak, Yasir Razak

Format: Article
Diterbitkan: Wolters Kluwer Medknow Publications 2015-06-01

Deskripsi

Thoracic surgery requires lung isolation which is usually achieved by placing a double lumen tube (DLT). Correct placement of DLT is crucial for lung isolation. In this case report incomplete lung isolation with DLT was corrected using a Fogarty catheter to achieve lung isolation successfully.