Bundle-branch reentry ventricular tachycardia after transcatheter aortic valve replacement
oleh: Adriana de la Rosa Riestra, José Amador Rubio Caballero, Alfonso Freites Estévez, Javier Alonso Belló, Javier Botas Rodríguez
Format: | Article |
---|---|
Diterbitkan: | Elsevier 2015-09-01 |
Deskripsi
An 83-year-old male suffering from severe symptomatic aortic valve stenosis received an implant of a biological aortic prosthesis through the femoral artery without complications. Seven days after dischargement he experienced a syncope. The patient was wearing an ECG holter monitor that day, which showed a wide QRS complex tachycardia of 300 beats per minute. The electrophysiological study revealed a bundle-branch reentry ventricular tachycardia as the cause of the syncope. Radio-frequency was applied on the right-bundle branch. Twelve months later, the patient has remained asymptomatic.