Development and validation of a high‐sensitivity assay for measuring p217+tau in plasma
oleh: Gallen Triana‐Baltzer, Setareh Moughadam, Randy Slemmon, Kristof Van Kolen, Clara Theunis, Marc Mercken, Hartmuth C. Kolb
Format: | Article |
---|---|
Diterbitkan: | Wiley 2021-01-01 |
Deskripsi
Abstract Introduction Diagnosis of Alzheimer's disease (AD) based on amyloid beta (A), pathologic tau (T), and neurodegeneration (N) biomarkers in peripheral fluids promises to accelerate clinical trials and intercept disease earlier. Methods Qualification of a Simoa plasma p217+tau assay was performed, followed by clinical utility evaluation in a cohort of 227 subjects with broad A and T spectrum. Results The p217+tau plasma assay was accurate, precise, dilution linear, and highly sensitive. All measured samples were within linear range of the assay, presented higher concentration in AD versus healthy controls (P < .0001), and plasma and cerebrospinal fluid levels correlated (r2 = 0.35). The plasma p217+tau results were predictive of central T and A status (area under the curve = 0.90 and 0.90, respectively) with low false +/– rates. Discussion The assay described here exhibits good technical performance and shows potential as a highly accurate peripheral biomarker for A or T status in AD and cognitively normal subjects.