Optimal placement of D-STATCOM using sensitivity approaches in mesh distribution system with time variant load models under load growth

oleh: Atma Ram Gupta, Ashwani Kumar

Format: Article
Diterbitkan: Elsevier 2018-12-01

Deskripsi

In this paper, an approach for optimal placement of D-STATCOM in mesh distribution systems using sensitivity approaches is proposed. The main contributions of the paper are as follows: (i) Optimal D-STATCOM placement based on the new voltage sensitivity index in mesh distribution system, (ii) optimal D-STATCOM size determination for seasonal loads with load growth scenario, (iii) comparison of D-STATCOM placement and size determination with the existing sensitivity methods, and (iv) impact of optimal D-STATCOM placement on voltage stability margin enhancement, energy loss reduction and cost of energy savings.The results of voltage profile improvement, reduction in power losses, reduction in cost of energy loss, improved voltage stability margin, cost of energy loss savings, installation cost of D-STATCOM and annual savings are obtained for UK 38 bus practical mesh distribution system. Keywords: Mesh distribution system, Load model, D-STATCOM, Sensitivity indices, Loss reduction, Annual energy savings