Continuous Renal Replacement Therapy for Two Neonates With Hyperammonemia
oleh: Christopher Markham, Caroline Williams, Cory Miller, Dorothy K. Grange, T. Keefe Davis, Kenneth E. Remy, Kenneth E. Remy
Format: | Article |
---|---|
Diterbitkan: | Frontiers Media S.A. 2021-11-01 |
Deskripsi
Objectives: This study aims to assess the feasibility of using hemofiltration for ammonia clearance in low body weight infants with an inborn error of metabolism.Design: A study of two cases.Setting: Quaternary pediatric hospital (Saint Louis Children's Hospital) NICU and PICU.Patients: Infants <6 months of age with an ICD-9 diagnosis of 270.6 (hyperammonemia).Interventions: Continuous renal replacement therapy (CRRT).Measurements and Main Results: We measure serum ammonia levels over time and the rate of ammonia clearance over time. Continuous renal replacement therapy was more effective than scavenger therapy alone (Ammonulâ„¢) for rapid removal of ammonia in low weight infants (as low as 2.5 kg).Conclusions: Continuous renal replacement therapy is technically feasible in low weight infants with severe hyperammonemia secondary to an inborn error of metabolism.