Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Pseudo-Dynamic Tests on Frame–Shear Wall Structure with Precast Concrete Diaphragm
oleh: Chun Han, Xinhong Dong, Qunshan Su, Chunming Duan, Guoping Tian
Format: | Article |
---|---|
Diterbitkan: | MDPI AG 2024-04-01 |
Deskripsi
In order to study how to improve the spatial action of precast monolithic composite floor slabs, and examine replacing the cast-in-place surface layer for reducing the weight of structure, we used pseudo-dynamic tests on one-quarter scale models of two-span and three-story frame structures. The lateral load tests compared the stresses and displacements with a cast-in-place floor frame–shear wall structure (SJ1) and a precast monolithic floor frame–shear wall structure with X horizontal braces at the bottom of the floor (SJ2). The results show the X horizontal braces can improve the spatial action. Structural integrity (SJ2) as well as the effective transmission of the horizontal force can be ensured by additional X bracing at the bottom of the rigidity of the floor without a cast-in-place concrete topping. The results show that X horizontal braces more effectively transfer horizontal stress, which provides a beneficial reference for similar research.