Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Endovascular repair of aortic perforation and type B aortic dissection after axillary intra-aortic balloon pump insertion
oleh: Kelly Twohig, BS, Ashley J. Williamson, MD, Ross Milner, MD
Format: | Article |
---|---|
Diterbitkan: | Elsevier 2021-12-01 |
Deskripsi
We present the successful endovascular repair of an iatrogenic aortic dissection in a 57-year-old woman with decompensated heart failure. An intra-aortic balloon pump was inserted in the patient via a percutaneous axillary approach for circulatory support. Six days later, she developed symptoms of abdominal pain and lower extremity malperfusion. Computed tomography angiography demonstrated a type B aortic dissection with associated retroperitoneal hematoma secondary to aortic perforation. The patient underwent emergent endovascular aortic repair and intra-aortic balloon pump removal with return of lower extremity perfusion. She recovered well and underwent heart and kidney transplant less than 2 months postoperatively.