Bacillus Calmette-Guérin Cross-Contamination in the Operating Room: A Case Report

oleh: Jasmine Ko Aqua MPH, Jill Holdsworth MS, Eileen Burd PhD, Jesse T. Jacob MD, MSc, Susan M. Ray MD, Marcos C. Schechter MD

Format: Article
Diterbitkan: SAGE Publishing 2021-12-01

Deskripsi

Mycobacterium tuberculosis complex (MTBC) false-positive cultures are commonly attributed to laboratory cross-contamination, but cross-contamination in the operating room (OR) is seldom reported. We report an investigation of cross-contamination in the OR for our case patient, who underwent surgical intervention for a chronic, left-sided breast lesion. Although the case patient had never received Mycobacterium bovis bacillus Calmette-Guérin (BCG) vaccine or chemotherapy, a subsequent surgical sample culture was identified as MTBC by high-performance liquid chromatography and M. bovis BCG-type by genotyping. A collaborative false-positive investigation was initiated, and we discovered a cross-contamination event in the OR from a source case who received BCG intravesical instillation. Clinicians, public health, and infection control staff should be aware that MTBC cross-contamination in the OR is rare, but possible, and should recognize the importance of conducting thorough false-positive investigations.