Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Loop-Terminated Mach–Zehnder Interferometer Integrated with Functional Polymer for CO<sub>2</sub> Gas Sensing
oleh: Muhammad A. Butt
Format: | Article |
---|---|
Diterbitkan: | MDPI AG 2024-05-01 |
Deskripsi
In this work, a numerical study on the loop-terminated Mach–Zehnder interferometer (LT-MZI) structure for CO<sub>2</sub> gas sensing applications is carried out via the finite element method. The sensing arm is covered with a polyhexamethylene biguanide (PHMB) polymer which is highly receptive to CO<sub>2</sub> gas. The refractive index of the host material decreases due to the absorption of the CO<sub>2</sub> gas resulting in a shift in the interference pattern of the LT-MZI structure. As a result, a redshift in the wavelength is observed in the transmission spectrum of the device. The sensitivity of the device is estimated at 7.63 pm/ppm, 34.46 pm/ppm, and 74.78 pm/ppm for the sensing arm lengths of 5 µm, 10 µm, and 15 µm, respectively. The sensitivity can be further enhanced, however, at the cost of the bigger footprint of the device. Utilizing the innovative sensor design, a comprehensive range of CO<sub>2</sub> gas concentrations spanning from 0 to 524 ppm is effectively detected. This compact and highly sensitive device serves as a vital tool for monitoring indoor CO<sub>2</sub> levels, fostering a healthier breathing environment for all occupants.