Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
The Development and Evaluation of a High-Frequency Toroidal Transformer for Solid-State Transformer Applications
oleh: Abdul Shakoor, Azhar Ul Haq, Taosif Iqbal
| Format: | Article |
|---|---|
| Diterbitkan: | MDPI AG 2023-09-01 |
Deskripsi
The performance and efficiency of high-frequency transformers (HFTs) are significantly influenced by leakage inductance. To improve the efficiency of HFTs, it is crucial to consider the effects of leakage inductance during the design and analysis processes. This research study aims to investigate a high-frequency toroidal transformer by examining different magnetic materials (Ferrite, Amorphas, and Iron-Powdered Alloy), winding configurations (solid, twisted, and LITZ wire), and operating frequencies (10 kHz and 50 kHz). To validate the effectiveness of parametric optimization in enhancing the system efficiency, the designed toroidal HFT was constructed and tested in a 600/300 V 3 kW dual active bridge (DAB) converter. The leakage inductances were measured using a frequency sweeping LCR meter.