Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Dispositivo de posicionamiento de muestras biológicas para su irradiación en un canal radial de un reactor nuclear // Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor
oleh: Maritza Rodríguez - Gual, Felix Mas - Milián, Airton Deppman, Paulo Rogerio Pinto - Coelho
Format: | Article |
---|---|
Diterbitkan: | Instituto Superior Politécnico José Antonio Echeverría - Cujae 2010-05-01 |
Deskripsi
<strong><span style="font-family: Arial; font-size: small;"><strong><span style="font-family: Arial; font-size: small;"><p>Resumen</p></span></strong></span></strong><span style="font-family: Arial; font-size: x-small;"><span style="font-family: Arial; font-size: x-small;"><p>Por la demanda de un dispositivo experimental para el posicionamiento de las muestras biológicas</p><p>para su irradiación en un canal radial de un reactor nuclear de investigaciones en funcionamiento, se</p><p>construyó y se puso en marcha un dispositivo para la colocación y retirada de las muestras en la</p><p>posición de irradiación de dicho canal. Se efectuaron las valoraciones económicas comparando con</p><p>otro tipo de dispositivo con las mismas funciones. Este trabajo formó parte de un proyecto</p><p>internacional entre Cuba y Brasil que abarcó el estudio de los daños inducidos por diferentes tipos de</p><p>radiación ionizante en moléculas de ADN. La solución propuesta es comprobada experimentalmente,</p><p>lo que demuestra la validez práctica del dispositivo. Como resultado del trabajo, el dispositivo</p><p>experimental para la irradiación de las muestras biológicas se encuentra instalado y funcionando ya</p><span style="font-family: Arial; font-size: x-small;"><p>por 5 años en el canal radial # 3(</p></span></span></span><p><em><span style="font-family: Arial; font-size: x-small;"><em><span style="font-family: Arial; font-size: x-small;">BH#3</span></em></span></em><span style="font-family: Arial; font-size: x-small;"></span><p> </p><strong><span style="font-family: Arial; font-size: small;"><strong><span style="font-family: Arial; font-size: small;"><strong><span style="font-family: Arial; font-size: small;"><p>Palabras claves:</p></span></strong></span></strong></span><p> </p></strong><span style="font-family: Arial; font-size: x-small;"><p><span style="font-family: Arial; font-size: x-small;">reactor nuclear de investigaciones, dispositivo para posicionamiento de muestras,</span><p>___________________________________________________________________________</p><strong><span style="font-family: Arial; font-size: small;"><strong><span style="font-family: Arial; font-size: small;"><p>Abstract</p></span></strong></span></strong><span style="font-family: Arial; font-size: x-small;"><span style="font-family: Arial; font-size: x-small;"><p>For the demand of an experimental device for biological samples positioning system for irradiations</p><p>on a radial channel at the nuclear research reactor in operation was constructed and started up a</p><p>device for the place and remove of the biological samples from the irradiation channels without</p><p>interrupting the operation of the reactor. The economical valuations are effected comparing with</p><p>another type of device with the same functions. This work formed part of an international project</p><p>between Cuba and Brazil that undertook the study of the induced damages by various types of</p><p>ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which</p><p>demonstrates the practical validity of the device. As a result of the work, the experimental device for</p><p>biological samples irradiations are installed and operating in the radial beam hole #3(BH#3) for more</p><p>than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the</p><p>device. The designed device increases considerably the type of studies can be conducted in this</p><p>reactor. Its practical application in research taking place in that facility, in the field of radiobiology and</p><p>dosimetry, and so on is immediate.</p></span></span><strong><span style="font-family: Arial; font-size: x-small;"><strong><span style="font-family: Arial; font-size: x-small;"><strong><font face="Arial" size="2"><p>Key words:</p></font></strong></span></strong></span><p> </p></strong><span style="font-family: Arial; font-size: x-small;"><p><span style="font-family: Arial; font-size: x-small;">research nuclear reactor, sample positioning device, radial channel, appropriate technology.</span></p></span></p><p>canal radial, tecnología apropiada.</p></span></p><p><span style="font-family: Arial; font-size: x-small;">) del reactor nuclear de investigaciones brasileño IEA-R1 de</span><p> </p></p><p>acuerdo a los requisitos solicitados. El dispositivo construido incrementó los tipos de estudios que</p><p>pueden ser realizados en el reactor. Su aplicación práctica en el campo de la radiobiología y la</p><p>dosimetría es inmediata.</p>