Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Evaluation of Preformed Stainless Steel Crown′s Crazing by Various Sterilization Methods of Steam Autoclave: A Pilot Study
oleh: Shital DP Kiran, Megha C Patel, Rohan Bhatt, Kuntal Bhatt
| Format: | Article |
|---|---|
| Diterbitkan: | Wolters Kluwer Medknow Publications 2015-01-01 |
Deskripsi
Aim: To evaluate the crazing of preformed stainless steel crowns by two different temperatures of autoclave sterilization. Materials and Method: 15 stainless steel crowns (3M ESP) were divided into 3 groups namely Group 1(G1) which was taken as control, Group 2(G2) which underwent Steam autoclaving at 121c, 15psi pressure for 20 minutes and Group 3(G3) which underwent Steam autoclaving at 132c, 30psi pressure for 8 min. The changes on the vestibular surface were then scored for presence or absence of crazing by using stereomicroscopy. The data was then analysed. Results: In control group the surface was relatively smooth when observed under stereomicroscope. However, in Group 2 cracks involving one-third to one-half of the surface were seen under stereomicroscope. Similar results were obtained in Group 3. Conclusion: Technique of steam autoclaving of sterilization has harmful effect on the surface of stainless steel crowns.