Nanocrown electrodes for parallel and robust intracellular recording of cardiomyocytes

oleh: Zeinab Jahed, Yang Yang, Ching-Ting Tsai, Ethan P. Foster, Allister F. McGuire, Huaxiao Yang, Aofei Liu, Csaba Forro, Zen Yan, Xin Jiang, Ming-Tao Zhao, Wei Zhang, Xiao Li, Thomas Li, Annalisa Pawlosky, Joseph C. Wu, Bianxiao Cui

Format: Article
Diterbitkan: Nature Portfolio 2022-04-01

Deskripsi

Nanoelectrodes for measuring intracellular action potentials suffer from issues with success rate, signal strength and fabrication. Here, the authors report on a scalable technique which creates robust nanocrown electrodes with high success rates by electroporation and demonstrate the advance towards preclinical drug evaluation.