Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Experimental investigation of solar air heater duct with discrete V-rib integrated with staggered elements
oleh: Sumer Singh Patel, Atul Lanjewar
Format: | Article |
---|---|
Diterbitkan: | Taylor & Francis Group 2021-03-01 |
Deskripsi
This paper presents an experimental investigation of heat transfer and friction factor in a rectangular duct with discrete V-rib integrated with staggered elements. The Reynolds number (Re) of 3000–12,000, ratio of staggered element size to rib height (r/e) of 2–5.5, relative roughness pitch (p/e) of 12, relative roughness height (e/Dh) of 0.045, flow angle of attack (α) of 60°, relative gap width (g/e) of 1, relative staggered element position (p’/p) of 0.65 and number of gaps (Ng) of 6. The maximum augmentation in Stanton number is 1.90 times over the smooth duct and maximum thermal efficiency is obtained 86% corresponding to ratio of staggered element size to rib height (r/e) of 3.5.