Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
A High-Precision Mid-Infrared Spectrometer for Ambient HNO<sub>3</sub> Measurements
oleh: Nicolas Sobanski, Béla Tuzson, Philipp Scheidegger, Herbert Looser, Christoph Hüglin, Lukas Emmenegger
| Format: | Article |
|---|---|
| Diterbitkan: | MDPI AG 2022-11-01 |
Deskripsi
Precise and accurate measurements of ambient HNO<sub>3</sub> are crucial for understanding various atmospheric processes, but its ultra-low trace amounts and the high polarity of HNO<sub>3</sub> have strongly hindered routine, widespread, direct measurements of HNO<sub>3</sub> and restricted field studies to mostly short-term, localized measurement campaigns. Here, we present a custom field-deployable direct absorption laser spectrometer and demonstrate its analytical capabilities for in situ atmospheric HNO<sub>3</sub> measurements. Detailed laboratory characterizations with a particular focus on the instrument response under representative conditions for tropospheric measurements, i.e., the humidity, spectral interference, changing HNO<sub>3</sub> amount fractions, and air-sampling-related artifacts, revealed the key aspects of our method: (i) a good linear response (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mi>R</mi><mn>2</mn></msup></semantics></math></inline-formula> > 0.98) between 0 and 25 nmol<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mspace width="0.166667em"></mspace><mi>·</mi><mspace width="0.166667em"></mspace></mrow></semantics></math></inline-formula>mol<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mrow><mo>−</mo><mn>1</mn></mrow></msup></semantics></math></inline-formula> in both dry and humid conditions with a limit of detection of 95 pmol<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mspace width="0.166667em"></mspace><mi>·</mi><mspace width="0.166667em"></mspace></mrow></semantics></math></inline-formula>mol<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><msup><mrow></mrow><mrow><mo>−</mo><mn>1</mn></mrow></msup></semantics></math></inline-formula>; (ii) a discrepancy of 20% between the spectroscopically derived amount fractions and indirect measurements using liquid trapping and ion chromatography; (iii) a systematic spectral bias due to water vapor. The spectrometer was deployed in a three-week field measurement campaign to continuously monitor the HNO<sub>3</sub> amount fraction in ambient air. The measured values varied between 0.1 ppb and 0.8 ppb and correlated well with the daily total nitrates measured using a filter trapping method.