Point of care in nursery to diagnose pneumothorax in neonates by new use of LED torch

oleh: Deepak Sharma, Srinivas Murki, Tejo Pratap

Format: Article
Diterbitkan: Wolters Kluwer Medknow Publications 2016-01-01

Deskripsi

Baby, A preterm female infant, was born to a primi mother at 33 weeks of gestation with a birth weight of 1.5 kg. Tracheo-esophageal fistula was diagnosed on antenatal scan and was confirmed after birth. The infant underwent primary end-to-end anastomosis on day 2 of life and was sustained by mechanical ventilation postoperatively. On day 5 of life, when the baby was on setting of peak inspiratory pressure of 15 mm Hg/peak, end-expiratory pressure of 4 mm Hg, and FiO 2 of 30%, there was a progressive increase in pressure and oxygen requirement. Suspecting air leak transillumination test was executed with a new LED device (Vein Finder @MIHIR NICS, Hyderabad, India). Transillumination tests confirmed the pneumothorax. Chest tube was inserted and baby improved dramatically.