Experimental characterization of a single-shot spectrometer for high-flux, GeV-scale gamma-ray beams
oleh: N. Cavanagh, K. Fleck, M. J. V. Streeter, E. Gerstmayr, L. T. Dickson, C. Ballage, R. Cadas, L. Calvin, S. Dobosz Dufrénoy, I. Moulanier, L. Romagnani, O. Vasilovici, A. Whitehead, A. Specka, B. Cros, G. Sarri
Format: | Article |
---|---|
Diterbitkan: | American Physical Society 2023-10-01 |
Deskripsi
We report on the first experimental characterization of a gamma-ray spectrometer designed to spectrally resolve high-flux photon beams with energies in the GeV range. The spectrometer has been experimentally characterized using a bremsstrahlung source obtained at the Apollon laser facility during the interaction of laser-wakefield accelerated electron beams (maximum energy of 1.7 GeV and overall charge of 207±62 pC) with a 1 mm thick tantalum target. Experimental data confirms the possibility of performing single-shot measurements, without the need for accumulation, with a high signal-to-noise ratio. Scaling the results to photons in the multi-GeV range suggests the possibility of achieving percent-level energy resolution as required, for instance, by the next generation of experiments in strong-field quantum electrodynamics.