Find in Library
Search millions of books, articles, and more
Indexed Open Access Databases
Avaliação das unidades de coleta do Programa de Triagem Neonatal no Estado do Rio de Janeiro Evaluation of Neonatal Screening Program collection centers in the State of Rio de Janeiro
oleh: Judy Botler, Luiz Antonio Bastos Camacho, Marly Marques da Cruz
Format: | Article |
---|---|
Diterbitkan: | Instituto Materno Infantil de Pernambuco 2012-12-01 |
Deskripsi
OBJETIVOS: avaliar estrutura e processo das unidades de coleta (UC) e incluindo coleta e transporte das amostras, e busca ativa do Programa de Triagem Neonatal do Estado do Rio de Janeiro (PTN-RJ). MÉTODOS: foram selecionadas 66 das 422 UC existentes, conforme tipo, localização e volume de amostras. Foram aplicados questionário semi-estruturado e roteiros para observação direta e análise documental. Foram gerados escores para estrutura e processo para cada UC. Foram calculadas medianas da pontuação, avaliada a consistência interna do instrumento, correlação de escores entre estrutura e processo. RESULTADOS: o escore mediano global (máximo de 100) foi de 69,1 (variação: 50,5-86,6) para estrutura e 63,9 (variação: 46,9-77,4) para processo. O desempenho das UC foi semelhante em estrutura. Maternidades e PSF tiveram desempenhos superiores em processo, e UCB inferiores. O coeficiente alfa de Cronbach indicou alta consistência dos instrumentos para avaliação de estrutura (alfa=0,93) e processo (alfa=0,81). Os escores de estrutura e processo apresentaram fraca correlação (coeficiente de Pearson = 0,44; Spearman = 0,42). Diferenças nos escores médios entre tipos de UC demonstraram considerável magnitude, porém sem significância estatística (p=0,387). CONCLUSÕES: o desempenho global em estrutura e processo foi satisfatório. As deficiências foram encontradas na capacitação de profissionais e suprimento de material para coleta e educativo.<br>OBJECTIVES: evaluate the structure and process of collection centers with focus on specimen collection, transportation of tests and active search in the state of Rio de Janeiro's Neonatal Screening Program (PTN-RJ). METHODS: 66 of the 422 collection centers were chosen, according to type, location and workload volume. The evaluation tool employed during the research included: semi-structured questionnaires, guidelines for direct observation and document review. Scores were generated for both structure and process components assessment at each collection center. Median scores were then calculated, evaluated for internal analytical consistency, score correlation between structure and process components. RESULTS: the overall median score (maximum of 100) was 69.1 (variation: 50.5-86.6) for structure and 63.9 (variation 46.9-77.4) for process components. The performance of each collection center showed consistency among centers with similar structure. Maternity centers and Family Health Program Units (PSF) showed superior performance in their process components, with collection centers type B (UCB) showing lower performance with the same group of components. The Cronbach alpha coefficient indicated a high consistency of among the assessment tools for structure (alpha=0.93) and process components (alpha=0.81). The structure and process components scores showed weak correlation (Pearson coefficient = 0.44; Spearman = 0.42). Differences in mean scores among types of collection center showed considerable magnitude, but without statistical signi-ficance (p=0.387). CONCLUSIONS: the overall performance in structure and process components was satisfactory. Deficiencies were found in professional training and in availability of specimen collection and educational material.